Digi Sm-300 Scale User Manual |top|
Note: Calibration typically requires a physical "Span Switch" to be toggled, often located under the scale body. Turn on the scale and press the . Enter Z Mode ( [M] , [RE-ZERO] , [M] , [M] ). Hold [RE-ZERO] and type 8715 to enter CALIBRATION MODE .
Press and hold the key while sequentially typing 0418 or your model's designator code to index the sensor thresholds. digi sm-300 scale user manual
: If the scale is behaving erratically, a partial reset can be done in Z Mode by entering 99999 then [RE-ZERO] + [C] . Digi SM-300 Scale Operation Manual | PDF - Scribd Hold [RE-ZERO] and type 8715 to enter CALIBRATION MODE
Clear the platter and press to set the zero point. Digi SM-300 Scale Operation Manual | PDF -
Ensure the label liner passes cleanly through the internal optical sensor gate.
Treat the SM-300 like a laboratory instrument. Keep it clean, level, and calibrated, and it will return precise measurements every time.