Zentis Zp-64 [FULL]

| Interval | Action | | :--- | :--- | | | Check for unusual noise, vibration, or seal leakage. | | Weekly | Tighten gland packing nuts (1/6th turn). Grease external bearings (2 pumps of NLGI #2). | | Monthly | Inspect check valve balls and seats for pitting. | | Annually (2,000 hours) | Replace piston seals and cylinder liner O-rings. Recalibrate stroke length indicator. |

In the food industry, hygiene is the non-negotiable priority. The Zentis ZP-64 is constructed with a fully open-frame architecture. This design philosophy eliminates hidden crevices where bacteria could accumulate. The machine surfaces are polished to a specific roughness standard (Ra value) that discourages adhesion and facilitates easy cleaning. zentis zp-64