Disomat B Plus Manual Jun 2026

While the tells you how to run the machine, experienced geotechnical engineers know these secrets:

Many labs scan their QMS (Quality Management System) copies. If you are in an accredited lab (ISO 17025), you must have the current revision of the manual available. Outdated manuals lead to non-conformities during audits.

After the final layer, remove the collar. The manual instructs you to use a straightedge to trim excess soil, then weigh the wet soil. After drying (oven at 105°C), you calculate the dry density. Disomat B Plus Manual

| Symptom | Probable Cause (per Manual) | Solution | | :--- | :--- | :--- | | | Overheating of the electromagnetic clutch (common after 30 minutes continuous use). | Stop the test. Let the machine rest for 15 minutes. The manual suggests buying a backup rammer for high-volume labs. | | Irregular blow count | Dust on the optical sensor or loose wire to the counter. | Open the front panel (disconnect power first). Clean the sensor lens with isopropyl alcohol. | | Rammer fails to release | Worn rubber buffer inside the lifting head. | Replace the buffer (Part #DBP-078). The manual shows the disassembly diagram. | | Loud grinding noise | Dry bearing on the cam shaft. | Do not operate. Lubrication required via the grease nipple (Zerk fitting) – 2 pumps of lithium grease. | | Mold jumps off the holder | The locking lever is worn or the retaining pin is misaligned. | Inspect the cam lock. Replace the retaining pin per the exploded parts diagram in the manual. |

: Includes binary inputs (TTL level), binary outputs, and support for various fieldbus modules like Ethernet/IP Configuration Software: DISOPLAN B plus The system is managed via the DISOPLAN B plus PC software , which provides: Parameterization While the tells you how to run the

The contains bolded safety warnings that must be posted in the lab:

Without maintenance, the Disomat B Plus produces false data. The dedicates a full chapter to calibration. Here are the non-negotiable points: After the final layer, remove the collar

The manual guides the user through inputting mechanical data. For example, if setting up a belt weigher, the user must input the tare weight (weight of the belt per meter) and the weighing length . Errors in these inputs result in mathematically incorrect outputs, regardless of how well the load cells are calibrated.

The manual stresses that the machine must be perfectly level. If the base is not horizontal, the rammer will strike the mold eccentricity, damaging the mold and skewing density results. Use the adjustable rubber feet to level the unit, verifying with a spirit level across the mold-seating plate.

pixels) and a 30-key flexible membrane keyboard for manual data entry and multi-function operations. Preconfigured Applications